Filter
ENDURITY CORE (SINGLE CHAMBER)
Cardiac Rhytmic Management
Include 1 Lead, and 1 Peelaway, multi programable, Weight 19 Gr, Volume 10,4 cc, Connector IS-1, longevity provides 10 years of service life which is supported by a 5-year warranty, Autocapture, back up pacing 5 volts, MRI Full scan, SAR 2 watts/kg, Mode VVI, AAI, VVIR, AAIR.
PACEMAKER ENDURITY (SINGLE/DUAL CHAMBER)
Cardiac Rhytmic Management
Include 2 Lead, and 2 Peelaway, multi programable, Weight 19 Gr, Volume 10.4 cc, Connector IS-1, longevity provides 10 years of service life which is supported by a 10-year warranty, Autocapture, back up pacing 5 volts, MRIFull scan, SAR 2 watts/kg, Mode VVI, AAI, VVIR, AAIR, DDD, DDR
PACEMAKER ASSURITY (DUAL CHAMBER)
Cardiac Rhytmic Management
The only pacemaker with programmable AT/AF alerts specifically indicated for detecting atrial tachyarrhythmias, which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of AF5.
CRT - P ALLURE
Cardiac Rhytmic Management
Weight 27 gr, Volume 15 cc, Connector IS-1 (RA, RV, LV) which is supported by warranty, Autocapture, Av Mode VVI, VVIR, DDDR,
CRT - P QUADRA ALLURE MP
Cardiac Rhytmic Management
Weight 27 gr, Volume 15 cc, Connector IS-1 (RA, RV), Connector IS-4 (LV) which is supported by warranty, Autocapture, Multipoint Pacing with Sync Av Mode VVI, VVIR, DDDR, MRI full Scan.
ICD FORTIFY ASSURA (SINGLE/DUAL CHAMBER)
Cardiac Rhytmic Management
MRI Full Scan, RF Telemetry/Wireless, Size/Vol: 35cc/75G, Sleep Rate: Sensor, Fluid Monitoring, Rate Hysterisys, Max Shock Energy 40 j, ATP While Charging, Material: Titanium, Coating: Parylene, Deft Response Mode: VVI, VVIR, VOO, DDD, DDDR.
CRT - D QUADRA ASSURA
Cardiac Rhytmic Management
Weight 83 gr, Volume 40 cc, Connector IS-1(RA,)Df-4(RV) and IS-4 (LV) which is supported by warranty, Max Shock Energy 40 j, ATP While Charging, Material: Titanium, Coating: Parylene, Deft Response Autocapture, Mode VVI, VVIR, DDDR, MRI full Scan
CRT - D QUADRA ASSURA MP
Cardiac Rhytmic Management
CRT - D QUADRA ASSURA MP Weight 83 gr, Volume 40 cc, Connector IS-1(RA,)Df-4(RV) and IS-4 (LV) which is supported by warranty, Max Shock Energy 40 j, ATP While Charging, Material: Titanium, Coating: Parylene, Deft Response Autocapture, Multipoint Pacing with Sync Av Mode VVI, VVIR, DDDR, MRI full Scan.
MERLIN PATIENT CARE SYSTEM (PCS)
Cardiac Rhytmic Management
The Merlin™ Patient Care System is a new portable system that programs St. Jude Medical‘s implantable cardioverter defibrillators (ICDs) and pacemakers. It will better enable doctors and company reps to analyze and program St Jude devices.
QUANTIEN INTEGRATED FFR SYSTEM
Cardiac Rhytmic Management
The QUANTIEN™ system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display various physiological parameters based on the output from one or more electrodes, transducers or measuring devices.
INQWIRE GUIDE WIRE DIAGNOSTIC
Coronary Intervention
A New Standard for Diagnostic Guide Wires, Basins, Flush Hoops, and J-Straighteners.
DRAGONFLY OPTIS OCT IMAGING CATHETER
Cardiac Rhytmic Management
The Dragonfly OPTIS Imaging Catheter with the OCT Imaging System is intended for the imaging of coronary arteries and is indicated in patients who are candidates for transluminal interventional procedures. The Dragonfly OPTIS Imaging Catheter is intended for use in vessels 2.0 to 3.5 mm in diameter. The Dragonfly OPTIS Imaging Catheter is not intended for use in the left main coronary artery or in a target vessel which has undergone a previous bypass procedure.
PRESSUREWIRE AERIS – FFR
Cardiac Rhytmic Management
The PressureWire™ X Guidewire is indicated to direct a catheter through a blood vessel and to measure physiological parameters in the heart and in the coronary and peripheral blood vessels. Physiological parameters include blood pressure. The PressureWire™ X Guidewire can also measure blood temperature.
OPTIS MOBILE SYSTEM
Cardiac Rhytmic Management
Optical Coherence Tomography (OCT) is an imaging modality that uses near-infrared light to provide high-definition images of the artery with high precision allowing to access lesion characteristics and plaque burden for coronary artery disease. OCT provides automated, accurate measurements to help guide stent selection, placement, and deployment.
XIENCE (DRUG ELUTING STENT)
Coronary Intervention
An Everolimus eluting coronary stent system that leverages cobalt chromium technology, biocompatible fluorinated copolymer, and has one of the thinnest drug eluting stent struts available, while maintaining strength to support the vessel.
GRAFT MASTER
Coronary Intervention
The GRAFTMASTER RX is indicated for use in the treatment of free perforations in coronary vessels or saphenous vein bypass grafts. It is designed to save lives.
TREK
Coronary Intervention
Enhanced for confident post-dilatation and delivery in challenging cases. It’s Non-Compliance tends to concentrate dilatation force for precise post-dilatation and therefore achieving outstanding stent apposition.
HI-TORQUE
Coronary Intervention
A front-line guidewire designed for durability and kink resistance. It features moderate support, excellent flexibility, shaping ribbon for easy tip shaping, and excellent torque transmission.
SUPERA (PERIPHERAL STENT)
Endovascular Intervention
The Supera™ Peripheral Stent is indicated for the superficial femoral artery (SFA) and the proximal popliteal artery. Engineered by a unique interwoven wire technology, this nitinol stent offers physicians unmatched clinical outcomes.
ARMADA (BALLOON DILATATION)
Endovascular Intervention
Armada Balloon Catheter is intended for dilatation of lesions in the renal, iliac, femoral, popliteal, tibial, and peroneal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.
PROGLIDE (VESSEL CLOSURE)
Endovascular Intervention
A suturing device for closing the common femoral artery access site of patients who have undergone interventional catheterization procedures.
VASCULAR PLUG (PERIPHERAL EMBOLIZATION)
Endovascular Intervention
The Amplatzer Vascular Plug (AVP) is a cylindrical plug made of self-expanding nitinol wire mesh with precise delivery control, which can be used for a variety of vascular pathologies.
ADVANCE ANGIOGRAPHIC NEEDLE
Coronary Intervention
Advance angiographic needles combine an ergonomic hub, coated stainless steel, and tip sharpness with top clinical performance. Our Majestik 2 and 3 part needles offered in standard, Seldinger, or Cournand shields incorporate a blunt cannula with a solid, or hollow cutting stylet.
ASAPLP ASPIRATION CATHETER
Coronary Intervention
The ASAP kits are designed for the quick removal of fresh, soft emboli and thrombi from vessels of the arterial system.
BASIX COMPAK INDEFLATOR
Coronary Intervention
The Basix COMPAK inflation device is a 20 mL disposable device capable of producing a maximum pressure of 30 ATM. It features an easy-to-read luminescent display for low-light procedures. The gold standard inflation device for interventional balloon inflation.
CONCIERGE GUIDING EXCELLENCE AMPLATZ RI
Coronary Intervention
The Concierge is the first guiding catheter to offer guiding excellence with SUPERIOR PERFORMANCE in the features clinicians value most: kink resistance, backup support, an atraumatic tip, and 1:1 torque.
503HF-R MANIFOLD
Coronary Intervention
Clear polycarbonate body provides durability and visibility, Airless rotator enhances patient safety by minimizing the possibility of trapped air and creates more space for the clinician’s fingers.
PRELUDE INTRODUCER SHEATH
Coronary Intervention
The Prelude family of sheath introducers is a comprehensive product line offering excellent transitions, smooth insertion, and Highly radiopaque marker provides increased visibility of the sheath tip when using fluoroscopy.
HONOR/ Y CONNECTOR
Coronary Intervention
The easy push-pull mechanism of the Honor hemostasis valve allows single-handed manipulation to open and close the valve while introducing devices into the vasculature.
PERFORMA DIAGNOSTIC CATHETER
Coronary Intervention
Designed with all the torque you need, improved shaft strength for better pushability and large inner lumens for increased flow rates. The Performa line of catheters will help you reach your goal of excellent imaging in today’s cardiology environment.
HIGH PRESSURE TUBING
Coronary Intervention
Merit’s high-pressure tubing configurations offer both a fixed male connector and a rotating adapter connector. PVC tubing styles rated at 1200, 900, and 500 PSI (83, 62, and 34 Bar).
STOPCOCK
Coronary Intervention
Our larger, easy-grip handle makes a Marquis Stopcock effortless to grip and turn. Available in pressure ratings of 200, 500, and 1050 PSI. Luer options include rotator, swivel nut, fixed, and slip.
PRELUDE SYNC
Coronary Intervention
Hemostasis device designed specifically for distal radial artery access.